PRODUCT DATA

Technical Specifications

24 specifications
Application Single-Stage Standard Opening Valve for Direct Burner Ignition
Ignition Type Direct Burner Ignition
Type of Fuel Natural Gas
Regulator Standard
Capacity (Max) 370,000 BTU/h
Capacity (Min) 30,000 BTU/h
Operating Voltage 24 V AC
Inlet Connection Size 1/2 in
Outlet Connection Size 3/4 in
Regulation Type Standard Opening
Pressure Rating 1/2 psi, 3.5 kPa
Operating Pressure (Max) 1/2 psi
For Use With S89C, S89E, S89F, S87 Series 5 and later
Includes 3/4 in Straight Flange, Natural to LP Conversion Kit, 3/4 in x 1/2 in Reducer Bushing
Valve Body Pattern Straight Through
Ambient Operating Temperature (Max) 175 °F, 79 °C
Ambient Operating Temperature (Min) -40 °F, -40 °C
Approvals and Standards UL Component Recognized MCCZ2.MH5323, CSA International: 112395, American Gas Association design certificate:UP-70-69A, Canadian Gas Association design certificate: UP-70-69A, Australian Gas Association certified:4717, DELTA C: UP-70-69A
Color Gray
Mounting Type 0° to 90° in any direction from the upright position of the gas control knob, including vertically
Operating Frequency 60 Hz
Pilot Gas Outlet None
Product Height 5.38 in, 135 mm
Product Width 4.06 in, 104 mm